Data Center

Data Center Services

Mission-critical electrical inspection, Cx engineering & Uptime Tier advisory.

East Africa's data center electrical inspection, commissioning and Uptime Institute Tier certification specialist — led by an Accredited Tier Designer (ATD), operating across Kenya and the African continent.

Texas Solutech is East Africa's specialist for data center electrical inspection, commissioning engineering and Uptime Institute Tier certification advisory — led by an Accredited Tier Designer (ATD). We conduct third-party critical infrastructure inspections across Kenya, Uganda, Tanzania and the wider African continent, validating power distribution, UPS systems, diesel generators, earthing, cooling and fire-life-safety systems against IEC 60364, BS 7671, NFPA 75, NFPA 70E, ASHRAE TC 9.9 and Uptime Institute Tier Standards. Our non-invasive IR thermography, partial discharge testing and power quality analysis deliver zero downtime to active IT loads.

We provide third-party critical electrical infrastructure inspections and commissioning engineering for data centres — validating power distribution, cooling systems, UPS, emergency generation and fire-life-safety systems against IEC 60364, BS 7671, NFPA 75 and Uptime Institute Tier standards.

Led by an Accredited Tier Designer (ATD), our team prepares facilities for Uptime Institute Tier Certification and Tier Certification of Operational Sustainability (TCOS), ensuring peak uptime, energy efficiency and compliance from day one.

Key benefits

Uptime assurance

Rigorous Cx validates every critical path before go-live — no surprises on day one.

Tier certification ready

ATD-led gap analysis and advisory for Uptime Institute Tier II, III and IV.

PUE optimisation

Detailed thermal and power audits that reduce energy waste and lower operating costs.

Live-site safe

Non-invasive IR thermography and ultrasound testing with zero downtime to active IT load.

How we deliver

  1. 1

    Scope & standards mapping

    Define systems, applicable standards (IEC, NFPA, Uptime) and audit boundaries.

  2. 2

    On-site inspection

    IR thermography, airborne ultrasound, power-quality testing and checkpoint audits.

  3. 3

    Gap analysis & findings

    Classified non-conformities with severity ratings, photographic evidence and Danger Notifications for critical hazards.

  4. 4

    Report & certification support

    Prioritised findings, signed certificate of inspection and Uptime TCOS recertification support.

Frequently asked questions

Can you inspect live data centre equipment without disrupting operations?

Yes. We use non-invasive Method of Procedures (MOPs), including IR thermography and airborne ultrasound, to identify hotspots, partial discharge and insulation breakdown — all without taking any equipment offline.

Do you support Uptime Institute TCOS recertification?

Yes. Our audits map real-world electrical and mechanical operations to Uptime Tier III and IV requirements, serving as a rigorous pre-assessment ahead of official Uptime Institute site visits.

What standards do your data centre audits reference?

IEC 60364, BS 7671, NFPA 75, NFPA 70E, ASHRAE TC 9.9, NETA and Uptime Institute Tier Standards — with every checkpoint clause-referenced so findings can be cited by specific standard.

Where we deliver

Data Center Services across East Africa

Pick a country or city and we'll show you data center services tailored to that location — local hook, regulator and projects we've delivered there.

Countries

Kenyan cities

One call. One engineer. One plan that works.

Stop losing money to electrical faults, high energy bills or uncertified infrastructure. Get a free assessment from East Africa's most trusted engineering team — no paperwork, no commitment.