Data Center Services
Mission-critical electrical inspection, Cx engineering & Uptime Tier advisory.
Texas Solutech is East Africa's specialist for data center electrical inspection, commissioning engineering and Uptime Institute Tier certification advisory — led by an Accredited Tier Designer (ATD). We conduct third-party critical infrastructure inspections across Kenya, Uganda, Tanzania and the wider African continent, validating power distribution, UPS systems, diesel generators, earthing, cooling and fire-life-safety systems against IEC 60364, BS 7671, NFPA 75, NFPA 70E, ASHRAE TC 9.9 and Uptime Institute Tier Standards. Our non-invasive IR thermography, partial discharge testing and power quality analysis deliver zero downtime to active IT loads.
We provide third-party critical electrical infrastructure inspections and commissioning engineering for data centres — validating power distribution, cooling systems, UPS, emergency generation and fire-life-safety systems against IEC 60364, BS 7671, NFPA 75 and Uptime Institute Tier standards.
Led by an Accredited Tier Designer (ATD), our team prepares facilities for Uptime Institute Tier Certification and Tier Certification of Operational Sustainability (TCOS), ensuring peak uptime, energy efficiency and compliance from day one.
Key benefits
Uptime assurance
Rigorous Cx validates every critical path before go-live — no surprises on day one.
Tier certification ready
ATD-led gap analysis and advisory for Uptime Institute Tier II, III and IV.
PUE optimisation
Detailed thermal and power audits that reduce energy waste and lower operating costs.
Live-site safe
Non-invasive IR thermography and ultrasound testing with zero downtime to active IT load.
How we deliver
- 1
Scope & standards mapping
Define systems, applicable standards (IEC, NFPA, Uptime) and audit boundaries.
- 2
On-site inspection
IR thermography, airborne ultrasound, power-quality testing and checkpoint audits.
- 3
Gap analysis & findings
Classified non-conformities with severity ratings, photographic evidence and Danger Notifications for critical hazards.
- 4
Report & certification support
Prioritised findings, signed certificate of inspection and Uptime TCOS recertification support.
Frequently asked questions
Can you inspect live data centre equipment without disrupting operations?
Yes. We use non-invasive Method of Procedures (MOPs), including IR thermography and airborne ultrasound, to identify hotspots, partial discharge and insulation breakdown — all without taking any equipment offline.
Do you support Uptime Institute TCOS recertification?
Yes. Our audits map real-world electrical and mechanical operations to Uptime Tier III and IV requirements, serving as a rigorous pre-assessment ahead of official Uptime Institute site visits.
What standards do your data centre audits reference?
IEC 60364, BS 7671, NFPA 75, NFPA 70E, ASHRAE TC 9.9, NETA and Uptime Institute Tier Standards — with every checkpoint clause-referenced so findings can be cited by specific standard.